Grundfos Magna 3 med CIM 200/CIU 200 enhet

Detaljer

Typ
Drivrutin
Upplaggd av
Ove Jansson, Abelko Innovation
Version
2
Uppdaterad
2013-04-19
Skapad
2013-04-07
Kategori
Modbus, Övrig utrustning, Vatten och avlopp
Visningar
4652

Beskrivning

The CIM 200 solution is an add-on communication module to be installed internally in a Grundfos E-pump (11-22 kW) or MAGNA3 pump, using a 10-pin connection. In this setup, the E-pump will supply power to the CIM 200.
The CIU 200 solution is a box with a power supply module and a CIM 200 Modbus module. It can either be mounted on a DIN rail or on a wall.

Bruksanvisning

Beror på instruktionen för respektive pump

Juridisk information

Alla skript tillhandahålls i befintligt skick och all användning sker på eget ansvar. Felaktig använding kan leda till skadad eller förstörd utrustning.

Skript kod

% Skapad med Modbus Creator
DEVICETYPE Grundfos NAMED "Grundfos" TYPEID 21341 IS

 PARAMETER
  Id       : "Adress";
  V14 : "wControlMode" [""];
  V15 : "wOperationMode" [""];
  V16 : "wSetpoint" ["%"]DEC2;

 PUBLIC
  V1 : "StatusRegister" ["bits"];
  V2 : "ProcessFeedback" ["%"]DEC2;
  V3 : "ControlMode" [""];
  V4 : "OperationMode" [""];
  V5 : "AlarmStatus" [""];
  V6 : "Head" ["bar"]DEC3;
  V7 : "VolumeFlow" ["m3/h"]DEC1;
  V8 : "Speed" ["rpm"]DEC1;
  V9 : "ActualSetpoint" ["%"]DEC2; % according to control mode
  V10 : "PumpLiquidTemp" ["K"]DEC2;
  V11 : "AuxSensorInput" ["%"]DEC2;
  V12 : "UserSetpoint" ["%"]DEC2;
  V13 : "DiffPressure" ["bar"]DEC3;

 PRIVATE
  count3;
  count6;
  tmp;

 BAUDRATE 9600;
 CHECKSUM MODBUS SWAPPED;

 TELEGRAM Read3 NAMED "Read 3" IS
  QUESTION
   DATA[0] := BYTE(Id); % Enhetens Modbus adress
   DATA[1] :=  HEX(03); % Modbus kommando för att läsa register
   DATA[2] <- RWORD(
    IF(count3>12) THEN count3 := 0; ENDIF;
    IF (count3=0) THEN tmp := 200;
    ELSIF (count3=1) THEN tmp := 201;
    ELSIF (count3=2) THEN tmp := 202;
    ELSIF (count3=3) THEN tmp := 203;
    ELSIF (count3=4) THEN tmp := 204;
    ELSIF (count3=5) THEN tmp := 300;
    ELSIF (count3=6) THEN tmp := 301;
    ELSIF (count3=7) THEN tmp := 303;
    ELSIF (count3=8) THEN tmp := 307;
    ELSIF (count3=9) THEN tmp := 321;
    ELSIF (count3=10) THEN tmp := 324;
    ELSIF (count3=11) THEN tmp := 337;
    ELSIF (count3=12) THEN tmp := 338;
    ENDIF;
    DATA:= tmp;
   );
   DATA[4] := RWORD(01);
  ANSWER SIZE 7   
   DATA[0] = BYTE(Id);
   DATA[1] = HEX(03);
   DATA[3] -> RWORD(
    IF (count3=0) THEN V1 := DATA;
    ELSIF (count3=1) THEN V2 := DATA/100;
    ELSIF (count3=2) THEN V3 := DATA;
    ELSIF (count3=3) THEN V4 := DATA;
    ELSIF (count3=4) THEN V5 := DATA;
    ELSIF (count3=5) THEN V6 := DATA/1000;
    ELSIF (count3=6) THEN V7 := DATA/10;
    ELSIF (count3=7) THEN V8 := DATA;
    ELSIF (count3=8) THEN V9 := DATA/100;
    ELSIF (count3=9) THEN V10 := DATA/100;
    ELSIF (count3=10) THEN V11 := DATA/100;
    ELSIF (count3=11) THEN V12 := DATA/100;
    ELSIF (count3=12) THEN V13 := DATA/1000;
    ENDIF;
    count3 := count3+1;
   );
  TIMEOUT 800
 END;

 TELEGRAM WriteRegister NAMED "Write Register" IS
  QUESTION
   DATA[0] := BYTE(Id); % Enhetens Modbus adress
   DATA[1] :=  HEX(06); % Modbus kommando för att skriva ett register
   DATA[2] <- RWORD(
    IF(count6>2) THEN count6 := 0; ENDIF;
    IF (count6=0) THEN DATA := 101;
    ELSIF (count6=1) THEN DATA := 102;
    ELSIF (count6=2) THEN DATA := 103;
    ENDIF;
   ); % Register adress
   DATA[4] <- RWORD(
    IF (count6=0) THEN DATA := V14;
    ELSIF (count6=1) THEN DATA := V15;
    ELSIF (count6=2) THEN DATA := V16*100;
    ENDIF;
    count6 := count6+1;
   );
  ANSWER SIZE 8
   DATA[0] = BYTE(Id);
   DATA[1] = HEX(06);
  TIMEOUT 800
 END;
END;