% Device definition for REGIN EXO Compact Alarm
%
% Settings module:
%       Parity: None
%       Baud:   9600
%       Mode:   RTU

% Author:  Ove Jansson, ABELKO AB Luleå 
% History: 2011-05-16 initial version
%
DEVICETYPE ReginAlarm NAMED "ReginAlarm" TYPEID 21423 IS 

  PARAMETER
  Id : "Adress";
  
  PUBLIC
    V1 :"LA1_TF"  ; % 0
    V2 :"FF1_ind"   ; % 1
    V3 :"SPJ3_4_Ständ/Ö"  ; % 2
    V4 :"SPJ3_4_Öppen/S"  ; % 3
    V5 :"Test_Omkoppl"  ; % 4
    V6 :"Service_OmkInd"  ; % 5
    V7 :"FF1_Man"  ; % 6
    V8 :"SPJ3_4_Man"  ; % 7
    V9 :"VP_Steg1_Man"  ; % 8
    V10 :"VP_Steg2_Man"  ; % 9
    V11 :"ASH2SA_LarmAMan"  ; % 10
    V12 :"ASH2SA_LarmBMan"  ; % 11
    V13 :"ASH2SA_LarmCMan"  ; % 12
 
  
  PRIVATE

  BAUDRATE 9600;

  CHECKSUM MODBUS SWAPPED;

  TELEGRAM ReadAlarm NAMED "ReadAlarmStatus" IS
    QUESTION
      DATA[0]  := BYTE(Id);      % Modbus unit address
      DATA[1]  := HEX(02);       % Modbus command "02h" read discrete input (bit)
      DATA[2]  := RWORD(0);      % Start adress
      DATA[4]  := RWORD(13);     % Number of inputs
      
    ANSWER SIZE 7
      DATA[0]   = BYTE(Id);
      DATA[1]   = HEX(02); 
      DATA[2]   = BYTE(2);
      DATA[3]  -> BYTE(IF (DATA & 1)   THEN V1 := 1; ELSE V1 := 0; ENDIF; % V1 :"FA1_Larm_Ind"  ""; % 0
                       IF (DATA & 2)   THEN V2 := 1; ELSE V2 := 0; ENDIF; % V2 :"FF1_ind"   ""; % 1
                       IF (DATA & 4)   THEN V3 := 1; ELSE V3 := 0; ENDIF; % V3 :"SPJ3_4_Ständ/Ö"  ""; % 2
                       IF (DATA & 8)   THEN V4 := 1; ELSE V4 := 0; ENDIF; % V4 :"SPJ3_4_Öppen/S"  ""; % 3
                       IF (DATA & 16)  THEN V5 := 1; ELSE V5 := 0; ENDIF; % V5 :"Test_Omkoppl"  ""; % 4
                       IF (DATA & 32)  THEN V6 := 1; ELSE V6 := 0; ENDIF; % V6 :"Service_OmkInd"  ""; % 5
                       IF (DATA & 64)  THEN V7 := 1; ELSE V7 := 0; ENDIF; % V7 :"FF1_Man"  ""; % 6
                       IF (DATA & 128) THEN V8 := 1; ELSE V8 := 0; ENDIF; % V8 :"SPJ3_4_Man"  ""; % 7
       ); 
       DATA[4]  -> BYTE(IF (DATA & 1)  THEN V9 := 1; ELSE V9 := 0; ENDIF; % V9 :"VP_Steg1_Man"  ""; % 8
                       IF (DATA & 2)   THEN V10 := 1; ELSE V10 := 0; ENDIF; % V10 :"VP_Steg2_Man"  ""; % 9
                       IF (DATA & 4)   THEN V11 := 1; ELSE V11 := 0; ENDIF; % V11 :"ASH2SA_LarmAMan"  ""; % 10
                       IF (DATA & 8)   THEN V12 := 1; ELSE V12 := 0; ENDIF; % V12 :"ASH2SA_LarmBMan"  ""; % 11
                       IF (DATA & 16)  THEN V13 := 1; ELSE V13 := 0; ENDIF; % V13 :"ASH2SA_LarmCMan"  ""; % 12
       );  

    TIMEOUT 2000

  END;
END;

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Device definition for REGIN EXO Compact Coil
%
% Settings module:
%       Parity: None
%       Baud:   9600
%       Mode:   RTU

% Author:  Ove Jansson, ABELKO AB Luleå 
% History: 2011-05-16 initial version
%
DEVICETYPE ReginCoil NAMED "ReginCoil" TYPEID 21424 IS 

  PARAMETER
    Id         : "Adress";
      
  PUBLIC
    V1  : "FA1_Start";   % 100  
    V2  : "VP1_Start";   % 101  
    V3  : "FF1_start";   % 102
  
  PRIVATE
    

  BAUDRATE 9600;
  CHECKSUM MODBUS SWAPPED;

  TELEGRAM ReadCoil NAMED "ReadCoil" IS
    QUESTION
      DATA[0]  := BYTE(Id);      % Modbus unit address
      DATA[1]  := HEX(01);       % Modbus command "01h" Read coil status (bit)
      DATA[2]  := RWORD(0);    % Start adress
      DATA[4]  := RWORD(3);      % Number of inputs
      
    ANSWER SIZE 6
      DATA[0]   = BYTE(Id);
      DATA[1]   = HEX(02); 
      DATA[2]   = BYTE(1);
      DATA[3]  -> BYTE(IF (DATA & 1)   THEN V1 := 1; ELSE V1 := 0; ENDIF;
                       IF (DATA & 2)   THEN V2 := 1; ELSE V2 := 0; ENDIF;
                       IF (DATA & 4)   THEN V3 := 1; ELSE V3 := 0; ENDIF;
      ); 

    TIMEOUT 2000

  END;
END;

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Device definition for REGIN EXO Compact Input
%
% Settings module:
%       Parity: None
%       Baud:   9600
%       Mode:   RTU

% Author:  Ove Jansson, ABELKO AB Luleå 
% History: 2011-04-05 initial version
%
DEVICETYPE ReginInput NAMED "ReginInput" TYPEID 21425 IS 
  
  PARAMETER
    Id       : "Adress";
   
  PUBLIC
    V1       : "FA1_GP1"  ["Pa"]; % 200
    V2       : "FA1_GT1" ["°C"]; % 202
    V3       : "UTE_GT3" ["°C"]; % 204
    V4       : "FA1_FO"  ["%"]; % 206
    V5       : "BörvärdeTryckst" ["Pa"];  % 208

    PRIVATE
    Sign;
    Exponent;
    Mantissa;
    Tmp3;

  BAUDRATE 9600;

  CHECKSUM MODBUS SWAPPED;
  
  TELEGRAM ReginInput1 NAMED "ReginInput1" IS
    QUESTION
      DATA[0]  := BYTE(Id);      % Modbus unit address
      DATA[1]  := HEX(04);       % Modbus command "04h" Read registers
      DATA[2]  := RWORD(0);    % OBS!! Register adress = Modbusadress in spec
      DATA[4]  := RWORD(10);     % Number of registers

    ANSWER SIZE 25   % antal register *2 + 5
      DATA[0]   = BYTE(Id);      % ID
      DATA[1]   = HEX(04);       % Modbus command "04h" Read registers
      DATA[2]   = BYTE(20);      % Byte count
      
      DATA[3] -> BYTE(Mantissa := DATA* 256;);
      DATA[4] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[5] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[6] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)*65536))/8388608);
        V1 := Sign * Mantissa * (2^Exponent);
      );
      DATA[7] -> BYTE(Mantissa := DATA * 256;);
      DATA[8] -> BYTE( Mantissa := Mantissa + DATA;);
      DATA[9] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[10] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)*65536))/8388608);
        V2 := Sign * Mantissa * (2^Exponent);
      );     
      DATA[11] -> BYTE(Mantissa := DATA *256;);
      DATA[12] -> BYTE( Mantissa := Mantissa + DATA;);
      DATA[13] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA & 127)*2;
      );
      DATA[14] -> BYTE(
        Exponent := Exponent+(DATA & 128)-127;
        Mantissa := 1+((Mantissa+((DATA & 127)*65536))/8388608);
        V3 := Sign * Mantissa * (2^Exponent);
      );
      DATA[15] -> BYTE(Mantissa := DATA *256;);
      DATA[16] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[17] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA & 127)*2;
      );
      DATA[18] -> BYTE(
        Exponent := Exponent+(DATA & 128)-127;
        Mantissa := 1+((Mantissa+((DATA & 127)* 65536))/8388608);
        V4 := Sign * Mantissa * (2^Exponent);
      );
      DATA[19] -> BYTE(Mantissa := DATA*256;);
      DATA[20] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[21] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[22] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)* 65536))/838860);
        V5 := Sign * Mantissa * (2^Exponent);
      );
     
    TIMEOUT 2000

  END;

END;

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Device definition for REGIN EXO Compact Input
%
% Settings module:
%       Parity: None
%       Baud:   9600
%       Mode:   RTU

% Author:  Ove Jansson, ABELKO AB Luleå 
% History: 2011-04-05 initial version
%
DEVICETYPE ReginHolding NAMED "ReginHolding" TYPEID 21426 IS 
  
  PARAMETER
    Id       : "Adress";
   
  PUBLIC
    V1       : "FF1_Brandfläkt"  [""]; % 300 1=till, 2=auto, 0=off
    V2       : "VP1_Steg1_Man" [""]; % 301 1=till, 2=auto, 0=off
    V3       : "VP1_Steg2_Man" [""]; % 302 1=till, 2=auto, 0=off
    V4       : "Börv_Högfart"  ["Pa"]; % 303 32bit
    V5       : "Börv_Lågfart" ["Pa"]; % 305 32bit
    V6       : "BlockHögfart"  ["°C"]; % 307 32bit Utetemperatur som blockerar högfart

    PRIVATE
    Tmp3;
    Sign;
    Exponent;
    Mantissa;

  BAUDRATE 9600;

  CHECKSUM MODBUS SWAPPED;
  
  TELEGRAM ReginHoldingt1 NAMED "ReginHolding1" IS
    QUESTION
      DATA[0]  := BYTE(Id);      % Modbus unit address
      DATA[1]  := HEX(03);       % Modbus command "03h" Read Holding registers
      DATA[2]  := RWORD(0);    % OBS!! Register adress = Modbusadress in spec
      DATA[4]  := RWORD(9);     % Number of registers

    ANSWER SIZE 23   % antal register *2 + 5
      DATA[0]   = BYTE(Id);      % ID
      DATA[1]   = HEX(03);       % Modbus command "03h" Read Holding registers
      DATA[2]   = BYTE(18);      % Byte count
      
      DATA[3] -> RWORD(V1 := DATA;);
      DATA[5] -> RWORD(V2 := DATA;);
      DATA[7] -> RWORD(V3 := DATA;);
      DATA[9] -> BYTE(Mantissa := DATA * 256;);
      DATA[10] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[11] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[12] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)*65536))/8388608);
        V4 := Sign * Mantissa * (2^Exponent);
      );
      DATA[13] -> BYTE(Mantissa := DATA * 256;);
      DATA[14] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[15] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[16] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)*65536))/8388608);
        V5 := Sign * Mantissa * (2^Exponent);
      );
      DATA[17] -> BYTE(Mantissa := DATA * 256;);
      DATA[18] -> BYTE( Mantissa := Mantissa + (DATA););
      DATA[19] -> BYTE(
        IF (DATA&128) THEN Sign := -1; ELSE Sign := 1; ENDIF; 
        Exponent := (DATA&127)*2;
      );
      DATA[20] -> BYTE(
        Exponent := Exponent+(DATA&128)-127;
        Mantissa := 1+((Mantissa+((DATA&127)*65536))/8388608);
        V6 := Sign * Mantissa * (2^Exponent);
      );
      
    TIMEOUT 2000

  END;

END;